Russia, Nizhnyaya Tura
st. Malysheva, 59

Phone

+7 (343) 422-62-70     
               
422-62-05

Feedback

Constructions

Fire-proof structures
Steel bulkhead class A-60
Steel bulkhead class A-60

General purpose fire-proof  steel bulkhead class A – effect of flame is possible both from isolation, and from metal.

Is used: Plates TIZOL-FLOT Fire 100

Fire-proof structures
Bounded steel bulkhead class A-60
Bounded steel bulkhead class A-60

Limited applicationfire-proof steel bulkhead –class A- 60 –effect of flame is possible only from isolation.

Is used: Plates TIZOL-FLOT Fire 100.

Fire-proof structures
Steel-hulled deck class А-30
Steel-hulled deck class А-30

The construction shall prevent the passage of smoke and flame for 30 minutes in a standard strength test.

Is used: Plates TIZOL-FLOT Fire 50.

Fire-proof structures
Steel-hulled deck class А-60
Steel-hulled deck class А-60

The construction shall prevent the passage of smoke and flame for 60 minutes in a standard strength test.

Is used: Plates TIZOL-FLOT Fire 100.

Fire-proof structures
Floating floor class А-60
Floating floor class А-60

Fire-proof steel floating floor class  A-60.

Is used: Plates TIZOL-FLOT Fire 150

Ship structures
Thermal insulation of ship structures with plates Tizol-Flot
Thermal insulation of ship structures with plates Tizol-Flot

According to rules IMO "Tizol-Flot" product  is nonflammable, possesses low coefficient of heat conductivity that allows to use it for thermal insulation, providing comfortable environment in shipboard space.

Is used: Plates TIZOL-FLOT 30-200

Ship structures
Thermal insulation of ship structures with basalt roll material
Thermal insulation of ship structures with basalt roll material

Is used: Basalt roll material MBOR without facing, or in facing withbasalt or glass-fiber fabric or foil on one side.

Ship structures
Thermal insulation of ship structures with basalt mats
Thermal insulation of ship structures with basalt mats

Is uswed:  Basalt mats pierced MPB without facing and in facing with fiberglass.

Joining units
Unilateral ribband
Unilateral ribband

Is used: A plate "Tizol-Flot" with a covering (aluminum foil, fiber glass fabric, fiberglass).

Joining units
Insulation of the internal isolated bulkhead joint place to the deck in the premises with decorative cladding
Insulation of the internal isolated bulkhead joint place to the deck in the premises with decorative cladding

Is used: A plate "Tizol-Flot" with a covering (aluminum foil, fiber glass fabric, fiberglass).

Joining units
Insulation of the internal isolated bulkhead joint place to the deck in the premises without decorative cladding
Insulation of the internal isolated bulkhead joint place to the deck in the premises without decorative cladding

Is used: A plate "Tizol-Flot" with a covering (aluminum foil, fiber glass fabric, fiberglass).

Joining units
Сonstructional unit ofribbands forfire-proof structures insulation
Сonstructional unit ofribbands forfire-proof structures insulation

Is used: A plate "Tizol-Flot" with a covering (aluminum foil, fiber glass fabric, fiberglass).

Joining units
Steelsheet cladding
Steelsheet cladding

Is used: A plate TIZOL-FLOT

Joining units
Connection of decks and bulkheads, class A-60 and A-0
Connection of decks and bulkheads, class A-60 and A-0

Is used: A plate TIZOL-FLOT Fire